Tobis, JJohnston, WDMontelli, SHenderson, ERoeck, WBauer, BNalcioglu, OHenry, W
In an attempt to improve visualization of the position of the guidewire and dilatation balloon during coronary angioplasty, a method was developed called digital coronary roadmapping. With this method a digitally acquired coronary angiogram is interlaced with the live fluoroscopic image of the guidewire and balloon catheter. The digital coronary an...
Tobis, JonathanNalcioglu, OrhanJohnston, Warren DQu, LianReese, TimSato, DavidRoeck, WernerMontelli, SteveHenry, Walter L
Quantitative measurements of coronary stenoses were made from digital coronary angiograms in 19 patients before and after percutaneous transluminal coronary angioplasty (PTCA). Two methods of measurement were compared. Mean stenosis before PTCA was 67 +/- 10% by the edge detection method and 67 +/- 12% by videodensitometry (difference not significa...
Pollock, Marc EEugene, JohnHammer-Wilson, MarieBerns, Michael W
The surface thrombogenicity of atheromas, conventional endarterectomy (CE), laser endarterectomy (LE), and laser angioplasty (LA) were compared in the rabbit arteriosclerosis model. Normal (N = 6) and arteriosclerotic (N = 15) rabbits underwent thoracoabdominal exploration. Multiple CEs and LEs were performed in 12 arteriosclerotic rabbits leaving ...
Recanalization of completely occluded superficial femoral or popliteal arteries was attempted in 18 patients with use of an Argon laser-mediated thermal probe. The length of the occluded segments varied between 0.5 and 26.0 cm, but 67% of the occlusions were greater than 9 cm long. The initial success rate was 67%. Arterial perforation occurred in ...
A prototype ultrasound imaging catheter was evaluated in vitro using 17 human atherosclerotic artery segments before and after balloon dilatation angioplasty. The catheter was 1.2 mm in diameter and incorporated a single 20-MHz ultrasound transducer to obtain cross-sectional images of the arterial lumen. In 15 of the 17 (88%) arteries, high quality...
Patients who are otherwise unsuitable candidates for coronary bypass surgery or standard coronary angioplasty (PTCA) may be successfully treated with PTCA during ECMO. Five patients (3 men, 2 women), with a mean age of 57 years, are reported on here. They were not considered good candidates for standard therapy because of poor left ventricular func...
Tobis, Jonathan M.Mahon, DonaldMoriuchi, MasahitoMallery, John A.Lehmann, KennethGriffith, JamesGessert, JamesZalesky, PaulMcRae, MichaelDwyer, Mary-Lynn
...
Because conventional imaging methods are inadequate for evaluating human coronary arteries in vivo, an intravascular ultrasonic imaging catheter was developed that allows the arterial wall to be studied in cross-section from within the artery. The catheter incorporates a mechanically rotating 20-MHz transducer, which is designed so that the ringdow...
BackgroundIntravascular ultrasound imaging was performed in 27 patients after coronary balloon angioplasty to quantify the lumen and atheroma cross-sectional areas.Methods and resultsA 20-MHz ultrasound catheter was inserted through a 1.6-mm plastic introducer sheath across the dilated area to obtain real-time images at 30 times/sec. The ultrasound...