Affordable Access

Why low powdered activated carbon addition reduces membrane fouling in MBRs

Authors
  • Remy, M.J.J.
  • Potier, V.
  • Temmink, B.G.
  • Rulkens, W.H.
Publication Date
Jan 01, 2010
Source
Wageningen University and Researchcenter Publications
Keywords
Language
English
License
Unknown
External links

Abstract

Previous research had demonstrated that powdered activated carbon (PAC), when applied at very low dosages and long SRTs, reduces membrane fouling in membrane bioreactor (MBRs). In this contribution several mechanisms to explain this beneficial effect of PAC were investigated, including enhanced scouring of the membrane surface by PAC particles, adsorption of membrane foulants by PAC and subsequent biodegradation and a positive effect of PAC on the strength of the sludge flocs. It was concluded that the latter mechanism best explains why low dosages of PAC significantly reduce membrane fouling. Cheaper alternatives for PAC may have a similar effect

Report this publication

Statistics

Seen <100 times