Vital dyes and light sources for chromovitrectomy: comparative assessment of osmolarity, pH, and spectrophotometry.

Authors
  • Costa, Elaine de Paula Fiod
  • Rodrigues, Eduardo B
  • Farah, Michel Eid
  • Dib, Eduardo
  • Penha, Fernando
  • Magalhães, Octaviano Jr
  • Furlani, Bruno Albuquerque
  • Lima Filho, Acácio A S
  • de Miranda, Antônio
  • Maia, Mauricio
Type
Published Article
Journal
Investigative Ophthalmology & Visual Science
Publisher
Association for Research in Vision and Ophthalmology (ARVO)
Publication Date
Jan 01, 2009
Volume
50
Issue
1
Pages
385–391
Identifiers
DOI: 10.1167/iovs.08-2285
PMID: 18689696
Source
Medline
License
Unknown

Abstract

Vital dyes showed variable osmolarity and pH, which also depended on the solvent used. Interaction of light from endoillumination source and vital dye may increase or decrease the risk for toxicity, making appropriate selection of both a desirable way to minimize the risk for phototoxic effects.