The saturation aspects of a large aperture (0.3 m) scintillometer operating over a 10-km path were investigated. Measurements were made over mainly forested, hilly terrain with typical maximum sensible heat fluxes of 300-400 W m(-2), and over flat terrain with mainly grass, and typical maximum heat fluxes of 100-150 W m(-2). Scintillometer-based fluxes were compared with eddy-correlation observations. Two different schemes for calculating the reduction of scintillation caused by saturation were applied: one based on the work of Hill and Clifford, the other based on Frehlich and Ochs. Without saturation correction, the scintillation fluxes were lower than the eddy-correlation fluxes; the saturation correction according to Frehlich and Ochs increased the scintillometer fluxes to an unrealistic level. Correcting the fluxes after the theory of the Hill and Clifford gave satisfying results.