Roof runoff contamination: Establishing material-pollutant relationships and material benchmarking based on laboratory leaching tests.

Authors
  • De Buyck, Pieter-Jan1
  • Matviichuk, Olha2
  • Dumoulin, Ann3
  • Rousseau, Diederik P L4
  • Van Hulle, Stijn W H5
  • 1 Laboratory for Industrial Water and Ecotechnology (LIWET), Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University Campus Kortrijk, Sint-Martens-Latemlaan 2B, B-8500, Kortrijk, Belgium. Electronic address: [email protected]. , (Belgium)
  • 2 Laboratory for Industrial Water and Ecotechnology (LIWET), Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University Campus Kortrijk, Sint-Martens-Latemlaan 2B, B-8500, Kortrijk, Belgium; Institut de Chimie des Milieux et Matériaux de Poitiers (IC2MP), UMR 7285, University of Poitiers, 4 rue Michel Brunet, TSA 51106, 86073 Poitiers Cedex 9, France. Electronic address: [email protected]. , (Belgium)
  • 3 Laboratory for Industrial Water and Ecotechnology (LIWET), Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University Campus Kortrijk, Sint-Martens-Latemlaan 2B, B-8500, Kortrijk, Belgium. Electronic address: [email protected]. , (Belgium)
  • 4 Laboratory for Industrial Water and Ecotechnology (LIWET), Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University Campus Kortrijk, Sint-Martens-Latemlaan 2B, B-8500, Kortrijk, Belgium. Electronic address: [email protected]. , (Belgium)
  • 5 Laboratory for Industrial Water and Ecotechnology (LIWET), Department of Green Chemistry and Technology, Faculty of Bioscience Engineering, Ghent University Campus Kortrijk, Sint-Martens-Latemlaan 2B, B-8500, Kortrijk, Belgium. Electronic address: [email protected]. , (Belgium)
Type
Published Article
Journal
Chemosphere
Publication Date
Nov 01, 2021
Volume
283
Pages
131112–131112
Identifiers
DOI: 10.1016/j.chemosphere.2021.131112
PMID: 34182629
Source
Medline
Keywords
Language
English
License
Unknown

Abstract

Because roofs represent a major part of the urban impervious surface, it is hypothesized that roof runoff is an important source of urban stormwater contamination. However, the contribution of different roofing materials to this contamination has only been examined to a limited extent. In this study, a resource and time efficient methodology, which uses some of the principles of a standardized leaching test (CEN/TS16637-2), was developed to identify material-pollutant relationships for sixteen commonly used roofing materials (EPDM, PVC, TPO, EVA, PU and bitumen membranes). Metals were detected in concentrations ranging from several μg/L in the leachate of synthetic materials up to 2.5 mg/L for Zn in the leachate of EPDM materials. Cd and Cr were not detected in any of the leachates. Furthermore, polycyclic aromatic hydrocarbons were detected in most leachates, with phenanthrene and naphthalene being most frequently detected in concentrations up to 4.5 μg/L for naphthalene. Further insights on organic pollutants' leaching from the tested materials were obtained by a non-target GC-MS screening of the leachates. Several commonly used additives such as flame retardants and light stabilizers were detected. Although no information on long-term leaching and material behavior under outdoor conditions could be obtained by the developed methodology, the laboratory test results could be used to benchmark the materials for their potential impact on roof runoff quality by the calculation of material indexes (which summarize the material-pollutant relationships). EPDM and PU roofing materials were identified as the materials having the highest potential to affect roof runoff quality. Copyright © 2021 Elsevier Ltd. All rights reserved.