Affordable Access

Optimal Frequency Range Selection for PZT Transducers in Impedance-Based SHM Systems

Authors
Publication Date
Source
Repositório Institucional UNESP
Keywords
  • Frequency
  • Impedance
  • Lead Zirconate Titanate (Pzt) Ceramics
  • Structural Engineering
External links

Abstract

Piezoelectric transducers of PZT (lead zirconate titanate) have been widely used in structural health monitoring (SHM) systems based on the electromechanical (E/M) impedance technique. In this technique, damages in the structure are identified by measuring the electrical impedance of the transducer in an appropriate frequency range. Usually, the selection of the correct frequency range to detect and evaluate damage is obtained by trial and error methods. In this paper, it is proposed a formal procedure to determine the frequency ranges in which the PZT transducers are more sensitive for damage detection. Tests were carried out on specimens with different sizes and there was a good match between the theoretical and practical results.

There are no comments yet on this publication. Be the first to share your thoughts.

Statistics

Seen <100 times
0 Comments