Affordable Access

Access to the full text

Novel flat and wide meniscal repair material improves the ultimate load of knot breakage in a porcine trans-capsular meniscal repair model

Authors
  • Yokoi, Hiroyuki1
  • Mae, Tatsuo2
  • Iuchi, Ryo3
  • Take, Yasuhiro1
  • Tachibana, Yuta3
  • Shimomura, Kazunori1
  • Ohori, Tomoki2
  • Shino, Konsei3
  • Yoshikawa, Hideki2
  • Nakata, Ken1
  • 1 Osaka University Graduate School of Medicine, Medicine for Sports and Performing Arts, Department of Health and Sports Science, 2-2, Yamada-oka, Suita, Osaka, 565-0871, Japan , Osaka (Japan)
  • 2 Osaka University Graduate School of Medicine, Department of Orthopaedic Surgery, 2-2, Yamada-oka, Suita, Osaka, 565-0871, Japan , Osaka (Japan)
  • 3 Yukioka Hospital, Sports Orthopaedic Surgery Center, 2-2-3, Ukita, Kita-ku, Osaka, Osaka, 530-0021, Japan , Osaka (Japan)
Type
Published Article
Journal
Journal of Experimental Orthopaedics
Publisher
Springer Berlin Heidelberg
Publication Date
Dec 19, 2017
Volume
4
Issue
1
Identifiers
DOI: 10.1186/s40634-017-0114-4
Source
Springer Nature
Keywords
License
Green

Abstract

BackgroundIn the meniscal repair procedures, a high ultimate load capacity and low cyclic creep at the repair site are favorable and lead to good biological incorporation of the tear site after surgery. Previous biomechanical tensile tests of the meniscal sutures have identified the suture knot as the weakest point. We hypothesized that the strength of a suture knot depends on the suture shape, and therefore, we compared three differently shaped suture materials composed of the same material and quantity per length. The purpose of this study was to determine whether a novel flat and wide repair material (FWRM), which consists of braided multi-threads that are cross-sectionally flat and wide, improves the ultimate load of knot breakage in a biomechanical experiment using a porcine trans-capsular meniscal repair model.MethodsEighteen fresh-frozen porcine knees (n = 6 in each group) were used. A longitudinal tear in the middle segment of the medial meniscus was created and repaired with a trans-capsular inside-out method using the following suture materials: No. 2–0 braided polyester conventional suture, hollow suture, and FWRM. After the separation of the inner segment of the meniscus with leaving, the suture stability of the repaired menisci was biomechanically analyzed with a video camera system for widening after a cyclic load between 5 and 20 N was applied 300 times. Ultimate failure load and stiffness at 5 mm/ min were also analyzed.ResultsWe found no significant difference in suture widening after cyclic load tests [conventional suture, mean 0.51 mm (S.D. 0.39 mm); hollow suture, mean 0.23 mm (S.D. 0.11 mm); and FWRM, mean 0.54 mm (S.D. 0.08 mm)]. The failure mode in all specimens was knot breakage. Compared with those of the other groups, the ultimate failure load of FWRM was statistically significantly higher in the load-to-failure tests (conventional suture, mean 58.8 N [S.D. 8.25 N]; hollow suture, mean 79.4 N [S.D. 10.2 N]; and FWRM, mean 97.4 N [S.D. 3.65 N]; p < 0.05).ConclusionFWRM improves the ultimate load of knot breakage without altering stability. This material may contribute to safe and stable meniscus repair.