Affordable Access

Publisher Website

Minimal residual disease detection in multiple myeloma: comparison between BML single-tube 10-color multiparameter flow cytometry and EuroFlow multiparameter flow cytometry.

Authors
  • Sato, Kota1
  • Okazuka, Kiyoshi2
  • Ishida, Tadao2
  • Sakamoto, Jun3
  • Kaneko, Shigeto3
  • Nashimoto, Junichiro2
  • Uto, Yui2
  • Ogura, Mizuki2
  • Yoshiki, Yumiko2
  • Abe, Yu2
  • Maeda, Aki3
  • Hamazaki, Hiroyuki3
  • Tsukada, Nobuhiro2
  • Hiragohri, Yuji3
  • Suzuki, Kenshi2
  • 1 Department of Hematology, Japanese Red Cross Medical Center, 4-1-22 Hiroo, Shibuya-ku, Tokyo, Japan. [email protected]. , (Japan)
  • 2 Department of Hematology, Japanese Red Cross Medical Center, 4-1-22 Hiroo, Shibuya-ku, Tokyo, Japan. , (Japan)
  • 3 Cellular Immunology Section, BML Incorporation, Tokyo, Japan. , (Japan)
Type
Published Article
Journal
Annals of Hematology
Publisher
Springer-Verlag
Publication Date
Dec 01, 2021
Volume
100
Issue
12
Pages
2989–2995
Identifiers
DOI: 10.1007/s00277-021-04634-5
PMID: 34430990
Source
Medline
Keywords
Language
English
License
Unknown

Abstract

Minimal residual disease (MRD)-negative status in multiple myeloma (MM) is associated with favorable outcomes. Although EuroFlow next-generation flow (NGF) is a global standard for MRD detection, its operating cost is high. Therefore, it is desirable to develop a less expensive method with equivalent sensitivity to that of EuroFlow-NGF. In this study, we compared the analytical ability of our BML 10-color multiparameter flow cytometry (MFC) to that of EuroFlow-NGF. Bone marrow samples collected from 51 patients with MM were subjected to MRD detection using BML 10-color-MFC and EuroFlow-NGF. Our antibody panel consisted of CD38 multiepitope, CD138, CD45, CD56, CD19, CD27, CD81, CD117, cytoplasmic immunoglobulin (cIg) κ, and cIgλ in a single tube. The median percentages of total plasma cells, as per 10-color-MFC and EuroFlow-NGF, were 0.2148% and 0.2200%, respectively, with a good correlation between the methods (r = 0.950). The median percentages of myeloma cells determined via 10-color-MFC and EuroFlow-NGF were 0.0012% and 0.0007%, respectively, with a strong correlation (r = 0.954). Our 10-color-MFC demonstrated high sensitivity to detect MRD; the results showed a good correlation with those obtained using EuroFlow-NGF. Therefore, our cost-effective single-tube MFC (approximately 100 USD/sample) is a promising alternative method for the detection of MRD in patients with MM. © 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Report this publication

Statistics

Seen <100 times