Affordable Access

Longterm results of 1 CU accommodative intraocular lens implantation: 2-year follow-up study.

Authors
Type
Published Article
Journal
Acta ophthalmologica Scandinavica
Publication Date
Volume
85
Issue
4
Pages
409–414
Identifiers
PMID: 17403026
Source
Medline

Abstract

Patients implanted with 1 CU IOLs lost their accommodation capacities with time because of the high incidence and degree of anterior and posterior capsule opacification. The accommodative lens material and design may have played a role in capsule fibrosis.