Affordable Access

Interventional treatment of lateral tunnel dehiscence in a total cavopulmonary connection using a balloon expandable covered stent.

Authors
  • Richens, T
  • Houston, A B
  • Ruiz, C
  • Wilson, N
Type
Published Article
Journal
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Publication Date
Aug 01, 2000
Volume
50
Issue
4
Pages
449–451
Identifiers
PMID: 10931620
Source
Medline
License
Unknown

Abstract

In this paper we present a patient with dehiscence of an intra-atrial tunnel previously constructed during a total cavopulmonary connection procedure. We describe the use of a custom made covered stent to seal off the dehisced segment, and abolish the intra-cardiac shunting. We believe this is the first account of such a procedure being undertaken.