The initial U.S. experience with the Tempo active fixation temporary pacing lead in structural heart interventions.

Authors
  • Nazif, Tamim M1, 2
  • Chen, Shmuel2
  • Codner, Pablo1
  • Grossman, Paul M3
  • Menees, Daniel S3
  • Sanchez, Carlos E4
  • Yakubov, Steven J4
  • White, Jonathan5
  • Kapadia, Samir5
  • Whisenant, Brian K6
  • Forrest, John K7
  • Krishnaswamy, Amar5
  • Arshi, Arash4
  • Orford, James L6
  • Leon, Martin B1, 2
  • Dizon, José M1
  • Kodali, Susheel K1, 2
  • Chetcuti, Stanley J3
  • 1 Columbia University Irving Medical Center, New York, New York.
  • 2 Clinical Trials Center, Cardiovascular Research Foundation, New York, New York.
  • 3 University of Michigan Cardiovascular Center, Ann Arbor, Michigan.
  • 4 OhioHealth/Riverside Methodist Hospital, Columbus, Ohio.
  • 5 Cleveland Clinic Heart & Vascular Institute, Cleveland, Ohio.
  • 6 Intermountain Medical Center Heart Institute, Salt Lake City, Utah.
  • 7 Yale University School of Medicine, New Haven, Connecticut.
Type
Published Article
Journal
Catheterization and Cardiovascular Interventions
Publisher
Wiley (John Wiley & Sons)
Publication Date
Apr 01, 2020
Volume
95
Issue
5
Pages
1051–1056
Identifiers
DOI: 10.1002/ccd.28476
PMID: 31478304
Source
Medline
Keywords
Language
English
License
Unknown

Abstract

This multicenter retrospective study of the initial U.S. experience evaluated the safety and efficacy of temporary cardiac pacing with the Tempo® Temporary Pacing Lead. Despite increasing use of temporary cardiac pacing with the rapid growth of structural heart procedures, temporary pacing leads have not significantly improved. The Tempo lead is a new temporary pacing lead with a soft tip intended to minimize the risk of perforation and a novel active fixation mechanism designed to enhance lead stability. Data from 269 consecutive structural heart procedures were collected. Outcomes included device safety (absence of clinically significant cardiac perforation, new pericardial effusion, or sustained ventricular arrhythmia) and efficacy (clinically acceptable pacing thresholds with successful pace capture throughout the index procedure). Postprocedure practices and sustained lead performance were also analyzed. The Tempo lead was successfully positioned in the right ventricle and achieved pacing in 264 of 269 patients (98.1%). Two patients (0.8%) experienced loss of pace capture. Procedural mean pace capture threshold (PCT) was 0.7 ± 0.8 mA. There were no clinically significant perforations, pericardial effusions, or sustained device-related arrhythmias. The Tempo lead was left in place postprocedure in 189 patients (71.6%) for mean duration of 43.3 ± 0.7 hr (range 2.5-221.3 hr) with final PCT of 0.84 ± 1.04 mA (n = 80). Of these patients, 84.1% mobilized out of bed with no lead dislodgment. The Tempo lead is safe and effective for temporary cardiac pacing for structural heart procedures, provides stable peri and postprocedural pacing and allows mobilization of patients who require temporary pacing leads. © 2019 Wiley Periodicals, Inc.