The effect of elemental and hydrocarbon impurities on mercuric iodide gamma ray detector performance

Authors
Journal
Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment
0168-9002
Publisher
Elsevier
Publication Date
Volume
380
Identifiers
DOI: 10.1016/s0168-9002(96)00296-3
Keywords
  • Section I. Growth And Material Properties

Abstract

Abstract Mercuric iodide is a room temperature semiconductor material that is used for gamma ray and x-ray radiation detection. Mercuric iodide is synthesized from mercuric chloride and potassium iodide and is then purified by a series of melts and sublimation steps and by zone refining. The mercuric iodide is grown into crystals and platelets and then fabricated into detectors. Elemental contamination may be a determining factor in the performance of these detectors. These contaminates may be present in the starting material or may be introduced during, or be unaffected by, the purification, growth or fabrication steps. Methods have been developed for the analysis of trace levels of elemental contamination. Inductively Coupled Plasma/Mass Spectroscopy (ICP/MS), Inductively Coupled Plasma/Optical Emission Spectroscopy (ICP/OES) and Gas Chromatography/Mass Spectroscopy (GC/MS) are used to determine sub ppm levels of many trace elemental impurities. Trace levels of many elemental impurities in the raw mercuric iodide are significantly reduced during the purification and zone refining processes. Though the levels of impurities are reduced, poor performing mercuric iodide detectors have contamination levels remaining or reintroduced which are higher for Ag, Al, Ca, Cu, Mg, Mn, Na, Pb and Zn than detectors with good gamma ray response. This paper will discuss the analytical methodology, the effects of purification on impurity levels, and the correlation between detector performance and impurity levels.

There are no comments yet on this publication. Be the first to share your thoughts.

Statistics

Seen <100 times
0 Comments

More articles like this

Characterization of silver impurities in mercuric...

on Journal of Crystal Growth Jan 01, 1996

Gamma-ray spectrometry with thick mercuric iodide...

on Nuclear Instruments and Method... Jan 01, 1983

Parallel pulse processing for mercuric iodide gamm...

on Nuclear Instruments and Method... Jan 01, 1986

Electrodrift purification of mercuric iodide for i...

on Nuclear Instruments and Method... Jan 01, 1996
More articles like this..