Two-phase pressure drop, boiling heat transfer, and critical heat flux to water in a small-diameter horizontal tube

Authors
Journal
International Journal of Multiphase Flow
0301-9322
Publisher
Elsevier
Publication Date
Volume
28
Issue
6
Identifiers
DOI: 10.1016/s0301-9322(02)00019-8
Keywords
  • Pressure Drop
  • Boiling Heat Transfer
  • Critical Heat Flux
  • Small Channel
  • Horizontal Flow

Abstract

Abstract Two-phase pressure drop, boiling heat transfer, and critical heat flux to water were studied in a small horizontal tube of 2.98-mm inside diameter and 0.91-m heated length. Experiments were performed at a system pressure of 200 kPa, mass fluxes of 50–200 kg/m 2s, and inlet temperatures from ambient to 80 °C. Experimental results and comparisons with state-of-the-art predictive correlations are presented. Modifications were made to the Chisholm two-phase multiplier correlation and to the Argonne National Laboratory small-channel boiling heat transfer correlation to better predict the experimental data of the present study.