Affordable Access

[Factors which influence phosphorus removal in hemodialysis].

Authors
  • Gallar, P
  • Ortiz, M
  • Ortega, O
  • Rodríguez, I
  • Seijas, V
  • Carreño, A
  • Oliet, A
  • Vigil, A
Type
Published Article
Journal
Nefrología : publicación oficial de la Sociedad Española Nefrologia
Publication Date
Jan 01, 2007
Volume
27
Issue
1
Pages
46–52
Identifiers
PMID: 17402879
Source
Medline
License
Unknown

Abstract

Phosphate removal during dialysis is influenced by Plasma phosphate levels, the volume of blood that passed the dialyzer and the vascular access. Uniformity on time and membrane surface could explain the abs cense of influence in our case. The ultra filtration, dialysate flux, membrane permeability or on-line hemodiafiltration does not influence the phosphate removal. The new membrane helixone with 2,1 m2 (Fresenius Fx100) increases phosphate removal probably because the membrane surface is higher.