Affordable Access

Determination of cefmetazole residue at pharmaceutical manufacturing facilities by chemiluminescence flow injection analysis.

Authors
Type
Published Article
Journal
Journal of Pharmaceutical and Biomedical Analysis
0731-7085
Publisher
Elsevier
Publication Date
Volume
41
Issue
2
Pages
599–602
Identifiers
PMID: 16413735
Source
Medline

Abstract

Application of a sensitive and rapid flow injection analysis (FIA) method with luminol chemiluminescence detection for determination of trace amounts of cefmetazole (CMZ) in cephamycin antibiotic residue in pharmaceutical manufacturing facilities and on pharmaceutical manufacturing equipment has been investigated. The method was shown to be sensitive at a level of limit of detection of 0.06 ng/ml and for linear concentrations in the range of 0.3-1.5 ng/ml. Average recoveries of CMZ from stainless steel plates and glass plates were 62.1% and 60.1%, respectively, by adding 15 ng/100 cm2, and that of air sampling filters was 91.9% by adding 3 ng/filter. The proposed method has been successfully applied to the determination of CMZ residue in samples collected from an actual manufacturing facility and equipment. According to the results, no detectable CMZ residue was observed, therefore it was verified that no contamination had occurred to other pharmaceutical products manufactured in the facility.

There are no comments yet on this publication. Be the first to share your thoughts.

Statistics

Seen <100 times
0 Comments
F