Affordable Access

Control of life-threatening haemorrhage from the neck: a new indication for balloon tamponade.

Authors
Type
Published Article
Journal
Injury
0020-1383
Publisher
Elsevier
Publication Date
Volume
23
Issue
8
Pages
557–559
Identifiers
PMID: 1286913
Source
Medline

Abstract

We report the use of a Foley catheter, placed through the wound, to provide balloon tamponade of major bleeding from the neck and supraclavicular fossae. In 10 consecutive explorations for exsanguinating injury in these regions balloon tamponade was used eight times, and was judged to be fully effective in four patients, partly effective in one, and ineffective in three patients.