Affordable Access

An analysis of the SEU rate of microcircuits exposed by the various components of space radiation.

Authors
Type
Published Article
Journal
Radiation measurements
Publication Date
Volume
30
Issue
3
Pages
427–433
Identifiers
PMID: 11543146
Source
Medline

Abstract

In the present paper the experimental and calculated data of SEU rate in microcircuits operating onboard spacecraft are compared. The main features of models and the calculation methods, which are incorporated in the SEREIS software package, are considered. The main features of models, and the calculation methods are considered. The contribution of the different space radiation components (ERB Protons; GCR particles and SEPs) to the SEU rate is discussed with an allowance for the shielding thickness.