Affordable Access

[Analysis of imidacloprid and damanlin by high performance liquid chromatography].

Authors
  • He, J
  • Chang, J B
  • Guo, R Y
  • Liu, P
  • Lin, S F
  • Chen, R F
  • Wang, Q
Type
Published Article
Journal
Se pu = Chinese journal of chromatography / Zhongguo hua xue hui
Publication Date
Mar 01, 2000
Volume
18
Issue
2
Pages
181–182
Identifiers
PMID: 12541605
Source
Medline
License
Unknown

Abstract

A new method for determination of imidacloprid and damanlin by using HPLC was established. It was carried out on a mu Bondapak C18 column (3.9 mm i.d. x 300 mm) with ACN-MeOH-H2O (60:10:30, V/V) as eluent and detected at 240 nm using photodiode array detector. The results of imidacloprid and damanlin were 3.71% and 15.65% respectively. The standard deviations for imidacloprid and damanlin were 0.88% and 0.76% respectively.