Ultrasound-enhanced tissue plasminogen activator thrombolysis in anin vitroporcine clot model

Authors
Journal
Thrombosis Research
0049-3848
Publisher
Elsevier
Publication Date
Volume
121
Issue
5
Identifiers
DOI: 10.1016/j.thromres.2007.07.006
Keywords
  • Ultrasound-Enhanced Thrombolysis
  • Stroke Therapy
  • Fibrinolysis
  • Therapeutic Ultrasound
  • Stable Cavitation
Disciplines
  • Medicine

Abstract

Abstract Introduction Thrombolytics such as recombinant tissue plasminogen activator (rt-PA) have advanced the treatment of ischemic stroke, myocardial infarction, deep vein thrombosis and pulmonary embolism. Objective To improve the efficacy of this thrombolytic therapy, the synergistic effect of rt-PA and 120 kHz or 1.0 MHz ultrasound was assessed in vitro using a porcine clot model. Materials and methods Fully retracted whole blood clots prepared from fresh porcine blood were employed to compare rt-PA thrombolytic treatment with and without exposure to 120-kHz or 1-MHz ultrasound. For sham studies (without ultrasound), clot mass loss was measured as a function of rt-PA concentration from 0.003 to 0.107 mg/ml. For combined ultrasound and rt-PA treatments, peak-to-peak pressure amplitudes of 0.35, 0.70 or 1.0 MPa were employed. The range of duty cycles varied from 10% to 100% (continuous wave) and the pulse repetition frequency was fixed at 1.7 KHz. Results For rt-PA alone, the mass loss increased monotonically as a function of rt-PA concentration up to approximately 0.050 mg/ml. With ultrasound and rt-PA exposure, clot mass loss increased by as much as 104% over rt-PA alone. Ultrasound without the presence of rt-PA did not significantly enhance thrombolysis compared to control treatment. The ultrasound-mediated clot mass loss enhancement increased with the square root of the overall treatment duration. Conclusions Both 120-kHz and 1-MHz pulsed and CW ultrasound enhanced rt-PA thrombolysis in a porcine whole blood clot model in vitro. No clear dependence of the observed thrombolytic enhancement on ultrasound duty cycle was evident. The lack of duty cycle dependence suggests a more complex mechanism that could not be sustained by merely increasing the pulse duration.

There are no comments yet on this publication. Be the first to share your thoughts.

Statistics

Seen <100 times
0 Comments