Affordable Access

Publisher Website

Dose intercomparison for 400–500 keV electrons using FWT-60 film and glutamine (spectrophotometric readout) dosimeters

Authors
Journal
International Journal of Radiation Applications and Instrumentation Part A Applied Radiation and Isotopes
0883-2889
Publisher
Elsevier
Publication Date
Volume
37
Issue
9
Identifiers
DOI: 10.1016/0883-2889(86)90247-9

Abstract

Abstract This paper describes the dose and the depth dose measurements with FWT-60 film and glutamine (Spectrophotometric readout) dosimeters for 400–500 keV electrons. The glutamine powder was spread uniformly in polyethylene bags and the powder thickness in each bag was 5 mg cm −2. Both techniques show a good agreement.