Comparison of the fracture strengths of metal-ceramic crowns and three ceromer crowns

Authors
Journal
Journal of Prosthetic Dentistry
0022-3913
Publisher
Elsevier - Mosby
Volume
88
Issue
2
Identifiers
DOI: 10.1067/mpr.2002.127712

Abstract

Abstract Statement of Problem. The fracture strength of a number of new ceromer systems for the fabrication of anterior fixed partial dentures is unknown. Purpose. The purpose of this study was to compare the fracture strengths of metal-ceramic crowns and 3 types of ceromer crowns in a simulated anterior tooth preparation. Material and Methods. A resin maxillary central incisor analog was prepared with a 5-degree convergence angle and a 90-degree, 1-mm shoulder. The incisal edge was reduced by 2 mm, and the axiogingival and axioincisal line angles were rounded. A mold of this tooth was made with vinyl polysiloxane impression material. Ten wax patterns were made from the mold and cast in a nickel-chromium alloy for the fabrication of metal dies, from which 10 metal-ceramic crowns were fabricated. Ten crowns for each of 3 ceromer systems (Artglass, Sculpture, and Targis) were fabricated from the same metal die. Each crown group was prepared, polymerized, air-particle abraded, and finished in accordance with the specific manufacturer's instructions. All 4 types of finished crowns were luted to the dies and embedded in polymethyl methacrylate resin blocks. Their fracture resistance was tested in a universal testing machine. The load was directed at the incisolingual line angle, at 130 degrees to the long axis of each specimen, until catastrophic failure occurred. A 7-mm-diameter rod was used to load the artificial crowns, with the center of the rod in contact with the crown surfaces. Analysis of variance and Tukey's multiple comparisons test (P<.05) were applied to the data. Results. Metal-ceramic crowns fractured at significantly higher values than ceromer crowns (1317 vs 602 N, respectively) (P<.05). No significant difference was found among the fracture values of Artglass, Sculpture, and Targis crowns. Conclusion. Within the limitations of this study, failure load values for the 3 ceromer crowns tested, although significantly lower than the values for metal-ceramic crowns, still exceeded normal occlusal forces. (J Prosthet Dent 2002;88:170-5.)

There are no comments yet on this publication. Be the first to share your thoughts.

Statistics

Seen <100 times
0 Comments

More articles like this

Comparison of the fracture strengths of metal-cera...

on The Journal of prosthetic dent... August 2002

Comparison of the fracture strengths of ceramometa...

on The Journal of prosthetic dent... July 1992

Comparison of the fracture strengths of ceramometa...

on Journal of Prosthetic Dentistr... Jan 01, 1992
More articles like this..