Reference values for echocardiographic measurements in urban and rural populations of differing ethnicity: The Strong Heart Study

Authors
Journal
Journal of the American Society of Echocardiography
0894-7317
Publisher
Elsevier
Volume
14
Issue
6
Identifiers
DOI: 10.1067/mje.2001.113258

Abstract

Abstract Discrepancies in reported reference values for left ventricular (LV) dimensions and mass may be due to imaging errors with early echocardiographic methods or effects of subject characteristics and inclusion criteria. To determine whether contemporary echocardiographic methods provide stable normal limits for left ventricular measurements in different populations, M-mode/2-dimensional echocardiography was applied in 176 American Indian participants in the Strong Heart Study and 237 New York City residents who were clinically normal. No consistent difference in any measure of LV size or function existed between populations. Upper normal limits (98th percentile) for LV mass were 96 g/m2 in women and 116 g/m2 in men and 3.27 cm/m for LV chamber diameter normalized for height. Thus contemporary M-mode/2D echocardiography provides reference ranges for LV measurements that approximate necropsy measurements and have acceptable stability in apparently normal white, African-American/Caribbean, and American Indian populations. (J Am Soc Echocardiogr 2001;14:601-11.)