Affordable Access

Publisher Website

Full-scale measurement of wind pressures on a 27·8 m long single 21·5 m span agricultural building

Authors
Journal
Journal of Agricultural Engineering Research
0021-8634
Publisher
Elsevier
Publication Date
Volume
26
Issue
1
Identifiers
DOI: 10.1016/0021-8634(81)90126-8
Disciplines
  • Agricultural Science
  • Design

Abstract

Abstract A full-scale experiment has provided basic wind load data for a single span ridged roof agricultural building. The results are presented as pressure coefficients for use with the design procedures of the British Standard Code of Practice CP3. Comparisons of measured pressure distributions with those given in CP3 show that for a transverse wind there is a good agreement but for a longitudinal wind the measured loads are markedly lower in magnitude than the Code values other than for the first few metres of roof from the windward end.