Torsello, Giovanni Bertoglio, Luca Kellersmann, Richard Wever, Jan J van Overhagen, Hans Stavroulakis, Konstantinos
Published in
Journal of vascular surgery
Endovascular repair of abdominal aortic aneurysms (AAAs) using the INCRAFT AAA Stent Graft System was safe and effective in regulatory approval studies. We herein report on the 1-year results of a real-world clinical study. The INSIGHT study is a multi-center, prospective, open label, post-approval study conducted to continually evaluate the safety...
Shaalan, Wael E El Emam, Ali A Lotfy, Hassan I Naga, Ahmad R
Published in
Vascular
Behcet's disease is a multisystem disorder of unknown etiology with vascular complications. This study reviewed the mid-term outcome of Behcet's disease patients with carotid artery pseudo-aneurysms treated by endovascular stent-graft repair at our unit. During a period of 11 years, six cases were included. Postoperative ultrasound duplex results w...
Takahashi, Satoshi Nishibe, Toshiya Kano, Masaki Akiyama, Shinobu Iwahashi, Toru Ogino, Hitoshi
Published in
Surgical case reports
Early type IIIb endoleak is a very rare complication of endovascular aneurysm repair (EVAR). An 87-year-old man was diagnosed with infrarenal abdominal aortic aneurysm. The patient underwent EVAR using the Endurant stent graft. Postoperative color duplex ultrasound revealed a regular row of pulsatile blood flow from the main body and left leg. The ...
Yuan, Bing Xin, Hai-nan Yuan, Kai Zhang, Jin-long Duan, Feng Wang, Mao-Qiang
Published in
Radiology Case Reports
Rupture of an internal carotid artery (ICA) pseudoaneurysm is a rare but life-threatening complication of irradiation therapy for a nasopharyngeal carcinoma (NPC). A 36-year-old man had a history of NPC treated with radiotherapy 8 years previously. He was admitted to the hospital because of severe repetitive epistaxis with hemodynamically instablil...
Premnath, Krishna Prasad Bellam Saleh, Ahmed Tarek Elsakhawy, Mahmoud Kutlay, Meric Jacob, Sabu
Published in
Journal of Clinical Imaging Science
Pseudoaneurysm with arteriovenous fistula is a rare presentation of penetrating trauma, occurs when trauma involves major blood vessels, and is traditionally treated surgically. Recently, these are more commonly treated using endovascular techniques which include stent graft placement and parent artery occlusion. In this case report, we present a c...
Narita, Akiko Ota, Toyohiro Yamamoto, Takahiro Ikeda, Shuji Izumi, Yuichiro Kitagawa, Akira Maruchi, Yuki Hagihara, Makiyo Ishiguchi, Tsuneo Suzuki, Kojiro
...
Published in
Minimally invasive therapy & allied technologies : MITAT : official journal of the Society for Minimally Invasive Therapy
Hemorrhage arising from the coronary sinus is very rare and can be lethal. It has historically been treated surgically. The present patient had coronary sinus rupture secondary to esophageal cancer and an abscess in the pericardium. Due to her poor general status, this patient was contraindicated for surgery and underwent endovascular therapy. The ...
Cha, Jung Guen Lee, Sang Yub Hong, Jihoon Park, Jong Min Lim, Kyoung Hoon Kim, Donghyeon
Published in
Trauma Case Reports
Iliac vein rupture resulting from blunt trauma is rare but can be fatal and challenging to diagnose despite thorough clinical investigation and image workup. Here, we present a case of traumatic iliac vein rupture managed by emergent endovascular repair using a bare-metal stent. Low pressure traumatic venous rupture is different from arterial ruptu...
Ozawa, Hirotsugu Shukuzawa, Kota Baba, Takeshi Tachihara, Hiromasa Ohki, Takao
Published in
Journal of Vascular Surgery Cases, Innovations and Techniques
At present, no consensus has been reached regarding the optimal management of stent graft thrombosis in the femoropopliteal artery. We present a case of long thrombosis of a Viabahn stent graft implanted in the superficial femoral artery that was successfully treated by thrombectomy using a trans-Viabahn approach at the mid-thigh segment. The advan...
Haraguchi, Takuya Kashima, Yoshifumi Tsujimoto, Masanaga Watanabe, Tomohiko Shitan, Hidemasa Sugie, Takuro Hachinohe, Daisuke Kaneko, Umihiko Kobayashi, Ken Kanno, Daitaro
...
Published in
CVIR Endovascular
BackgroundVascular calcification is a predictor of poor clinical outcome during and after endovascular intervention. Guidewire crossing techniques and devices have been developed, but chronic total occlusions (CTOs) with severe calcification often prevent subintimal re-entry. We propose a novel guidewire crossing approach combined needle rendezvous...
Ueda, Tatsuo Murata, Satoru Tajima, Hiroyuki Saito, Hidemasa Yasui, Daisuke Sugihara, Fumie Mizushima, Shohei Mine, Takahiko Kawamata, Hiroshi Hayashi, Hiromitsu
...
Published in
CVIR Endovascular
BackgroundA Viabahn stent graft (SG) is a heparin-coated self-expandable SG for lower extremity arterial disease that exhibits high flexibility and accuracy in the delivery system. This study aimed to evaluate the short-term efficacy and safety of emergency endovascular treatment (EVT) using a Viabahn SG for upper and lower extremity arterial bleed...